What you should pay attention to with underfloor heating: Whether laminate, vinyl or wood flooring - Kaindl floors can be installed over a hot water underfloor heating system without any problems. Modern electric underfloor heating systems or radiant heating systems can also be used without any problems. We have summarized the most important instructions, as well as tips for installation below.

The Thermal Resistance of Floor Coverings

Whether a floor covering is suitable for underfloor heating depends largely on its thermal conductivity. In order to achieve sufficient heat transfer to in the room to be heated, the heat transfer resistance should not be greater than 0.15 m² K/W. The thermal resistance of Kaindl floors is 0.06 - 0.09 m² K/W, and thus in a favorable range.

For heat requirements greater than 65 watts/m², we recommend the use of additional heating sources. For floating installation of Kaindl floors, it is essential to take into account the thermal resistance of the impact sound insulation used when determining the overall thermal resistance.

"Due to the natural foot warmth of Kaindl floors, the underfloor heating can also be switched off earlier during transitional periods. This can sometimes save heating costs.”

Sustainability tip
from the floor expert

Laying the floor on an underfloor heating system

Please observe the following instructions when installing a Kaindl floor on a hot water underfloor heating systems:

  • Screeds must be installed in accordance with industry standards. Basically, all mineral subfloors must be heated up before laying Kaindl floors so that no harmful moisture can escape.
  • The heating capacity must be brought up to the maximum heating capacity in daily 5° C increments. This is also important for each subsequent heating period. The period during which the heating must be run at full load depends on the screed type and screed thickness.
  • After this full load phase, the heating is lowered again in daily 5° C increments. For safety reasons, the heating screed is heated up again after a heating pause of 5-7 days (see appendix). If the heating up and down is done by the heating contractor, he should keep and present a heating protocol without being asked.
  • Prior to laying, a moisture measurement must be carried out at the points designated by screed layers or heating contractors using a CM device.
  • To check the dryness of the screed, lay out several pieces of PE foil (approx. 50 x 50 cm) and tape the edges. If after 24 hours no condensate has accumulated under the foil and the covered screed surface has remained the same color, the screed is dry and installation of the flooring can begin.
  • Before laying, the heating must be turned off for 1-2 days. The surface temperature of the screed must be at least 15° C, but max. 20° C during installation.

Modern electric underfloor heating systems and laminate

The general requirements mentioned above also apply to modern electric underfloor heating systems. The heating system must be approved by the manufacturer for installation under laminate flooring. Important information about the properties and operation of various underfloor heating systems can be found in our information sheet.

All details at a glance

Which vapor retarder should be used for underfloor heating?

Lay a PE film at least 0.2 mm thick over the entire surface as a vapor barrier. Overlap the sheets by at least 20 cm and glue them together. On the walls, the sheets must be pulled up 5 cm. The desired impact sound insulation is then laid on the PE foil. 24 hours after laying, the underfloor heating can be gradually increased to the desired heat output. The same applies to any heating period that begins.

Details and heating protocol